Safe

Good

27 May 2025

The service managed patient safety incidents well as part of an integrated safety and governance structure. Staff recognised and reported incidents and near misses. Managers investigated incidents and shared lessons learned with the whole team and the wider service. When things went wrong, staff apologised and gave patients honest information and suitable support. Staff had the required levels of training to safeguard vulnerable people and knew what actions to take to keep people safe from avoidable harm and abuse. There were extensive, multidisciplinary systems and pathways to maintain safe standards of care. Embedded throughout the service, staff had a demonstrable and exhaustive focus on patient safety. There was continuity of care when people moved between different services through a highly collaborative approach to care that included other specialist organisations. The design, maintenance and use of facilities, premises, and equipment kept people safe. The service had enough staff with the right skills, training and experience who received effective support, supervision, and development opportunities. The service controlled infection risk well and staff used control measures to protect patients, themselves and others from infection. The imaging service used systems and processes to safely prescribe, administer, record and store medicines according to national evidence-based practice.

This service scored 75 (out of 100) for this area. Find out what we look at when we assess this area and How we calculate these scores.

Learning culture

Score: 3

The learning culture was embedded across all departments and staff teams and was supported by clear and consistent support from the patient safety and experience team. The team prepared learning discussions for any incidents that resulted in moderate harm or above and shared these across every team. This approach promoted shared learning and empowerment in safety and meant staff could identify learning for their own practice even if the incident occurred in a different department. They used this approach to avoid risk and near misses in their own department. Staff discussed errors and omissions in a culture that valued honesty and openness to drive improvement. They responded quickly to embed learning and recommendations from incidents.

Recent incidents involved radiologists protocoling patients outside of their scope of practice and an X-ray foot pedal radiation exposure. This took place at the main hospital site and the patient safety and quality lead for diagnostics ensured learning was shared with all relevant teams. No patients or staff came to harm as a result of the incidents and staff discussed outcomes through monthly quality monitoring meetings and regular departmental and team meetings. The hospital’s executive team had oversight of all incidents and near miss reports through a tiered system of governance.

In the previous 6 months, staff reported 60 incidents in imaging, across all sites. Of these, 62% resulted in no harm to patients and 38% resulted in low levels of harm.

Safe systems, pathways and transitions

Score: 3

Subject matter experts worked with departmental and provider staff to establish and embed safe systems of working. These were evidence-based, in line with national standards, and were embedded across all aspects of the service.

The provider had implemented the patient safety incident response framework (PSIRF) tool. The tool is part of an NHS England patient safety process, which the patient safety team and clinical educators had adapted. Patient safety leads established an investigation team for each incident, including a patient experience lead, and worked with the responsible clinician to follow Duty of Candour guidance.

Staff used a critical, urgent, and unexpected findings policy to treat patients whose scans showed immediate or unexpected need.

Staff facilitated a consistently safe working environment focused on radiation safety and used national diagnostic reference levels (DRLs) to optimise radiation doses by body part or area.

The imaging team established a series of safe working protocols to manage the response to an emergency or unexpected event. This included transferring patients to the acute admissions unit if they fainted after a scan.

Staff followed national guidance for pre-scan pregnancy checks that could be potentially harmful to unborn babies.

Radiologists vetted and protocolled referrals within the provider’s electronic records system that ensured only qualified professionals made referrals.

Electronic patient record systems were integrated with imaging and point of care testing equipment, providing access to clinical records and facilitating auditing of safety tools including radiation dosage.

Radiographers ensured the same member of staff screened, positioned, and scanned the patient. This was good practice because it reduced the risk of errors.

Staff used a quality management system to access protocols and standardised procedures. This was an improved, single point of access system that contributed to sustainability and resilience.

Safeguarding

Score: 3

All staff completed safeguarding training to level 3, including for children and young people. While staff did not treat children in this clinic, they completed training in recognition that young people may be present when accompanying an adult patient. Staff knew how to contact safeguarding leads and could give examples of scenarios in which they would do so.

Involving people to manage risks

Score: 3

The service had established, risk management systems in place. Multidisciplinary by design, the clinically led systems were based on information sharing across the provider so that staff could learn from risks, near misses, and incidents in other departments. The imaging team met daily before the start of service to discuss the scans booked for the day, any capacity or staffing issues, and any pressures on the service. The imaging team from the provider’s 2 London sites joined the meeting, which helped to solve problems collaboratively. On one day of our inspection the MRI scanner at one site had failed and staff used the meeting to organise services to minimise impact or inconvenience on patients.

The medical physics expert and radiation protection supervisor monitored radiation doses by modality, patient condition, and over time.

Each diagnostic modality had clear guidance on how and when staff should canulate patients ready to administer pre-scan contrast. The guidance also included when patients should be identified and when staff should complete a contrast checklist as part of safe practices. We observed staff follow the system closely and were risk-averse in their delivery of care.

Safe environments

Score: 3

The service complied with IR(ME)R requirements, including use of lead-equivalent aprons for staff, with tracked and monitored exposure data. Radiation control areas were indicated with illuminated signs and hazard warning notices, in line with national guidance. Staff audited the maintenance and integrity of aprons.

There was a need for improvement in how staff exposed to ionising radiation adhered to the radiation dose policy. Each member of staff was issued with a radiation dose monitor badge. All-site audits showed inconsistent practice, with not all staff wearing their own badge. Compliance improved between April 2024 (71%) and November 2024 (100%), which met the provider’s 100% target.

The estates and facilities team provided engineering support for equipment failures and the provider had service contracts for specialist equipment with manufacturers, including urgent response agreements for critical equipment.

All staff completed practical evacuation training to support people using manual evacuation aids. Staff had taken part in a whole clinic simulated evacuation to identify how to most effectively use the evacuation lift for patients unable to leave using the stairs.

Staff followed a maintenance programme for imaging equipment. Using daily, weekly, and monthly checklists, they checked and documented cleanliness, functionality, and calibration. Audits from the previous 12 months showed consistently high levels of reliability.

The health, safety, and fire manager led audits and compliance activities to meet the requirements of the Control of Substances Hazardous to Health (COSHH) Regulations. The department held an inventory of COSHH substances and trained champions carried out monthly audits. The health and safety team monitored results and were in the process of adopting a risk-based approach that would streamline the frequency of safety checks.

The department was equipped with a full resuscitation trolley.

Safe and effective staffing

Score: 3

The imaging department operated on an outpatient basis and most scans were booked in advance with preplanned staffing levels. Radiographers carried out scans with support from nurses as part of wider care pathways. Radiologists were on site 4 days each week and staff could contact them at any time. Radiographer assistants provided a range of support within defined competencies. A cardiac physician and consultant cardiologist led a cardiac echocardiogram (ECG) service.

Most staff rotated between the provider’s 3 London sites. Bank staff and regular agency staff, all of whom undertook the same induction as substantive staff, supplemented the team. There was always an imaging lead on shift whenever the department was open

At the time of our assessment, 94% of staff were up to date with mandatory training and all staff had undergone supervision and an appraisal. As diagnostic imaging staff worked across all sites, this percentage was an overall department figure. Staff had access to external specialist courses, such as cardiac MRI training.

The team provided access to scans for patients referred on the day by consultants and GPs if staffing levels meant it was safe to do so.

Staffing levels were supplemented by radiologists who worked remotely. Records systems enabled secure access, ensuring on-demand radiologist input.

A cardiac physician and consultant cardiologist led a cardiac echocardiogram (ECG) service.

A resuscitation team was on duty at all times. Healthcare assistants and non-clinical staff completed basic life support training, and all other staff had training in immediate life support or above.

The induction programme was comprehensive and ensured staff understood and were confident applying, the local rules and The Ionising Radiation (Medical Exposure) Regulations 2017 (IR(ME)R) standards of practice. Staff undertook up to 6 weeks of modality training in addition to corporate and standard training, followed by a 6-month probationary period.

Infection prevention and control

Score: 3

We observed high standards of infection prevention and control (IPC) throughout the department. A dedicated housekeeping team maintained cleanliness and good hygiene in the environment and clinical staff used antibacterial procedures on equipment between patients. For example, staff use a disinfection process for ultrasound probes approved by the equipment manufacturer. This was in line with Department of Health and Social Care best practice guidance. Good hand hygiene practices were embedded in practice and staff undertook regular training.

Staff worked within a range of policies and standard operating procedures (SOPs) that provided assurance of consistent standards. Policies were in place for outbreaks and emergencies, such as viral haemorrhagic fever.

Staff with specialist training maintained cleanliness of the MRI safety zone to ensure hygiene was maintained whilst protecting staff from exposure to the magnetic field.

Staff monitored hand hygiene standards using monthly observational audits. In the previous 12 months, staff achieved 100% compliance in each audit, reflecting consistently good practice. This was a combined with outpatients. In the same period staff achieved 100% compliance with safe management of the care environment requirements.

Medicines optimisation

Score: 3

Medicines used within the imaging service were administered under patient group directions (PGDs), with oversight of each prescription by a radiologist. PGDs provide a legal framework that allows some registered health professionals to supply or administer a specified medicine to a pre-defined group of patients, without them having to see a prescriber. The most commonly used medicine was a contrast agent used during X-rays to help staff more clearly visualise arteries and veins.

Staff used steroids in ultrasound-guided injections and the pharmacy team maintained continuous monitoring and quality control in stock, dispensing, and administration. Staff followed good practice in documenting steroids used in each patient’s electronic record.

Some people experience allergic reactions to contrast, and staff used a protocol to minimise this risk and to provide immediate care if a reaction occurred. The service monitored updates from the Resuscitation Council UK regarding increased instances of anaphylaxis amongst patients who receive contrast media. The imaging team updated the SOP for managing anaphylaxis whenever new guidance was released and all staff who administered contrast were trained in immediate life support.