• Hospital
  • Independent hospital

North of England Hyperbaric Services Limited

Spire, Hull and East Riding Hospital, Lowfield Road, Anlaby, Hull, North Humberside, HU10 7AZ (01482) 659471

Provided and run by:
North of England Medical Hyperbaric Services Limited

Latest inspection summary

On this page

Background to this inspection

Updated 29 December 2015

North of England Medical Hyperbaric Services limited (NEMHS) was privately owned and managed by the technical and research director. NEMHS has been providing a service at the current location for 17 years.

The hyperbaric unit was located within the Spire Hull and East Riding private hospital. The unit provided hyperbaric (high-pressure) oxygen therapy for a range of conditions. The service was available to NHS and private patients of all ages and to military personnel.

Hyperbaric oxygen treatment involves breathing pure oxygen at higher than atmospheric pressures in an enclosed chamber. The atmospheric pressure was equivalent to being up to 40 feet under water. Hyperbaric therapy was used to treat a variety of medical conditions. These included decompression illness sustained after diving, the treatment of radiation tissue injury, treatment of necrotising wounds, carbon monoxide poisoning and gas embolism (air bubbles in the blood vessels). Treatment was available 24 hours a day all year round for emergency and elective patients. Elective patients received treatment every weekday for between four to six weeks.

Consultants, the coast guard, emergency departments, other emergency services, senior physiotherapists, and GPs referred patients to the service. Most patients were treated through a contract with NHS England before elective treatment commenced. Most elective patients could access the service within 1 – 2 hours from home. However, emergency patients could be referred from anywhere within England dependent on availability, clinical need and transport requirements. The unit treated all age groups.

There are CQC inspection frameworks for single speciality services such as hyperbaric services which were being tested in wave 1 (April 2015 – September 2015). Until October 2015, we were in the pilot phase for the single specialty services list and therefore we will not publish a rating. The team inspected the full hyperbaric service at this inspection.

There were no special reviews or investigations of the hospital by the CQC at any time previously. There had been no previous CQC inspections. The registered manager had worked at the service for nine years and been the manager for six years.

Overall inspection

Updated 29 December 2015

There was a small team of staff at the unit who all seemed to work well together. We found the technical director and nurse manager to be knowledgeable and skilled. They had a positive ethos towards good quality care. Both the technical director and nurse manager were visible and approachable.

We found the staff at the hyperbaric unit to be compassionate and caring. We saw staff had empathy and were aware of the whole care experience for patients, not just their hyperbaric treatment in isolation. The timing of the morning and afternoon sessions meant that most patients did not have to travel very early or return home late. There was flexibility for elective patients to attend sessions to fit in around their own routine.

We found emergency access to the service was good. Staff could be called in and the unit opened within an hour. Staff told us the average wait from referral to treatment was two months. We found this to be longer than some other hyperbaric units, which employ more staff and hence have more treatment sessions. The average wait for treatment in such other units was approximately two weeks.

There was no clear vision or set of values for North of England Hyperbaric Medical Services. This meant staff could not understand their role in achieving the vison for the service, and there was no way to monitor progress towards delivering any goals. The technical director told us there was no need for a strategy as staff demonstrated the values by the work carried out. We found no performance framework to identify, assess, monitor, and respond to performance issues. Staff told us they did not receive an annual appraisal. There were no staff surveys, staff meetings or ways the staff could be involved in developing the service.

Staff told us there was a strong focus on patient safety. Environmental audits commenced in August 2015 and were due to take place on a monthly basis. Maintenance records indicated staff carried out checks on a daily basis, for example, the oxygen and carbon dioxide levels within the chamber. However, we found the resuscitation equipment inside the chamber such as the ‘medic’ bag and airway bag were only checked on a monthly basis.

Staff were expected to complete mandatory training in their substantive posts outside the service. The nurse manager kept records of when mandatory training was due or completed by staff; however, we saw that mandatory training was out of date for several of the 10 staff. There was a potential service risk in medical support to the service highlighted in an external 2014 report and confirmed at inspection. The NHS England service specification indicated a paediatric consultant should oversee the treatment of children; we found this was not the case at North of England hyperbaric unit.