Safe

Good

20 November 2026

The service detected and controlled potential risks in the care environment. There was enough suitably trained staff to ensure patients were safe and the service met demand. The service managed infection risks well and made sure medicines and treatments were safe. 

Staff and patients felt able to raise concerns and learning from incidents was shared. Staff understood safeguarding processes, so patients were kept safe. 

Managers ensured staff completed relevant training and received regular appraisals to support the delivery of safe and effective care. Facilities and equipment were suitable for patients’ needs, clean, well maintained, and any identified risks were addressed. 

At our last inspection we rated this key question requires improvement. The service has made improvements. At this assessment the rating has changed to good. This meant people were safe and protected from avoidable harm. 

We have not awarded this service a score for Safe.

Find out about when we will not publish a key question score and what we look at when we assess Safe.

Learning culture

Score: 3

The service had a proactive and positive culture of safety, based on openness and honesty. They listened to concerns about safety and investigated and reported safety events. Lessons were learnt to continually identify and embed good practice. 

Staff told us they followed the service’s incident reporting process and were confident in identifying and reporting incidents and near misses. Staff demonstrated an understanding of what should be reported and how to submit reports on the electronic incident reporting system. From October 2025 to September 2026, 14 incidents had been reported, 13 of which were categorised as no harm and 1 low harm incident.  

There had been no incidents that met the reporting criteria under the Ionising Radiation (Medical Exposure) Regulations (IR(ME)R). IR(ME)R notifications are required when a patient receives a radiation dose significantly higher than intended. 

Managers investigated patient safety incidents and learning was shared. Staff described a learning culture where incidents were discussed in morning huddles, quarterly team meetings and in governance meetings. Incident summaries were produced and displayed on a staff learning board, called ‘learning on a page’ and staff could describe learning from a recent extravasation incident. A notifiable safety incident decision-making flowchart was displayed within the department to guide staff. 

Staff understood the duty of candour. Compliance with duty of candour training was 100%. Duty of candour means being open and honest with patients when something doesn’t go as planned. 

Safe systems, pathways and transitions

Score: 3

The service worked with people and healthcare partners to establish and maintain safe systems of care, in which safety was managed or monitored. They made sure there was continuity of care, including when people moved between different services. 

Maintaining patient safety throughout the diagnostic journey, from referral to completion of imaging, was a key focus for the service. Referrals were accepted only from authorised professionals in accordance with IR(ME)R requirements. There were processes to identify and escalate referrals submitted by individuals who were not approved referrers. All referrals were reviewed to confirm they contained sufficient information and that the requested examination was clinically justified and appropriate for the patient's needs. 

The service operated within clearly defined acceptance criteria to ensure care was delivered safely and within its capabilities. Patients underwent appropriate assessment before imaging took place, including the completion of relevant safety screening questionnaires and clinical checks to identify potential risks. Staff took action to address concerns when identified and worked closely with referrers and radiologists to support safe decision-making and patient care. 

Staff routinely applied recognised safety checks, including the ‘pause and check’ process. These checks were used to verify the patient’s identity, the examination being undertaken and the correct imaging modality. Pause and Check is a patient safety process used to help prevent errors immediately before an examination or procedure takes place. During our inspection, we observed staff completing these checks and recording the outcomes appropriately. The service monitored compliance through quarterly audits of the pause and check process. 

Staff worked with patients to identify and manage potential risks before imaging procedures were undertaken. Safety screening questionnaires were completed on arrival and used to assess whether there were any factors that could affect the safety of the examination. For example, magnetic resonance imaging (MRI) screening included checks for implanted medical devices, prostheses and pregnancy status. Patients attending for computed tomography (CT) examinations involving contrast media were assessed for risks such as allergies and renal function. Staff reviewed questionnaire responses before imaging took place and took appropriate action when concerns were identified. Staff told us radiologists were accessible if any risks needed to be discussed before imaging took place. 

Staff took appropriate steps to reduce identified risks and support patients to undergo imaging safely. For example, patients were provided with gowns where clothing contained metal components, such as zips, that could interfere with imaging procedures. Ear protection was available for patients undergoing scans where noise levels could be high. Staff had completed moving and handling training, enabling them to safely assist patients who required support when transferring onto imaging beds. 

Staff monitored and optimised radiation doses for each examination in line with the principle of keeping exposures as low as reasonably achievable' (ALARA), while still obtaining images of sufficient quality for diagnosis. This principle is a requirement of the Ionising Radiation (Medical Exposure) Regulations (IR(ME)R) and is recognised as a key standard for radiation protection. 

Local rules were available in all imaging suites. Local rules are department-specific safety instructions that staff follow to ensure radiation is used safely and in line with regulatory requirements. 

Urgent or unexpected imaging findings were identified and acted on promptly to ensure patients received timely follow-up care. Staff communicated significant findings to referrers or other appropriate clinicians and escalated concerns without delay when required. An urgent findings policy was available to guide staff practice. 

The service had arrangements in place to respond effectively if a patient’s condition deteriorated, including access to emergency equipment and appropriately trained staff. Ninety-one percent of staff had completed Level 2 Basic Life Support (BLS) training, and 100% of staff had completed Immediate Life Support (ILS) training and were also trained to recognise and manage allergic reactions. Staff could obtain timely clinical support from radiologists, outpatient consultants and the Resident Medical Officer (RMO) when required. In addition, the hospital had a dedicated resuscitation team with Advanced Life Support (ALS) training available to provide specialist support during medical emergencies. A daily resuscitation huddle was held by the team each morning. During the meeting, staff undertook emergency alarm checks and confirmed resuscitation team roles and responsibilities. This helped ensure staff understood their individual responsibilities and could respond effectively in an emergency. 

Staff took part in simulation training to prepare them for emergency situations. This included practical drills for MRI emergency evacuation procedures, enabling staff to safely remove patients from the scanner during time-critical incidents. Regular simulation exercises helped maintain staff competence and familiarity with emergency processes. The last drill was carried out in May 2026. 

Patient’s electronic records were stored securely, and staff could easily access information when needed.  

Care was planned and coordinated with patients and other healthcare providers to ensure a smooth transition between services when needed. When responsibility for a patient’s care was transferred, staff communicated effectively with the receiving team and shared relevant information to support ongoing treatment. Letters and clinical information were routinely copied to professionals involved in the patient's care, including their GP, to help ensure continuity and patient safety. 

Safeguarding

Score: 3

The service worked with patients and healthcare partners where required, to understand how best to keep people safe, what it meant for individuals and the best way to achieve that. Staff concentrated on protecting their right to live in safety, free from bullying, harassment, abuse, discrimination, avoidable harm and neglect. The service shared concerns quickly and appropriately. 

Staff demonstrated a good understanding of their responsibilities to safeguard patients. Training records showed 100% of staff had completed level 2 adult safeguarding training, and 91% had completed level 3 safeguarding training for adults and level 3 safeguarding training for children and preventing radicalisation training. The service had up-to-date safeguarding policies that reflected current national guidance for both adults and children, including arrangements for situations where children attended the service as visitors. 

Staff understood their responsibilities for identifying safeguarding concerns and knew when and how to make safeguarding referrals. Specialist safeguarding support was available, and staff were aware of how to access advice and guidance when required. The hospital had designated safeguarding leads for both adults and children who had completed level 4 safeguarding training. The registered manager had oversight of safeguarding within the service. The diagnostic service had not identified any concerns or made a safeguarding referral in the year before our inspection. 

Staff followed appropriate procedures to manage visitors attending the diagnostic imaging department safely. The service had a chaperone policy and information about chaperones was clearly displayed throughout the department to support patient awareness and choice.

Involving people to manage risks

Score: 3

The service worked with patients to understand and manage risks by thinking holistically. Staff provided care to meet patient’s needs which was safe, supportive and enabled patient to do the things that mattered to them. 

Patients were provided with information about their upcoming imaging examination, including any associated risks and how to prepare safely for their appointment. There were procedure-specific leaflets which included details about the examination, any precautions patients needed to take, and guidance for family members or companions. The MRI leaflet highlighted the importance of removing any metal items and identifying equipment that may not be safe in the MRI environment.  

Patients were told how and when their imaging results would be communicated to them. They were advised that results would be sent to the referring clinician. 

Staff completed assessments before imaging procedures to confirm patients could undergo their examination safely. They considered factors such as allergies, kidney function, pregnancy, medical history, previous adverse reactions, the presence of implants or pacemakers, and prior exposure to radiation. Modality-specific safety questionnaires were used to identify and manage these risks before the examination proceeded. 

Risk information was clearly displayed throughout the department to help patients understand potential safety concerns. For example, notices reminded patients to tell staff if they were pregnant before undergoing imaging procedures. 

Staff carried out checks to ensure patients did not have any items or clothing that could pose a risk during MRI examinations. Patients were provided with gowns where necessary to minimise these risks. Records we reviewed showed that safety questionnaires had been completed and reviewed by staff before procedures took place. 

All patients we spoke to felt well informed and understood what to expect from their care and treatment. They told us staff explained things in a way they could understand and involved them in making decisions.

Safe environments

Score: 3

The service detected and controlled potential risks in the care environment. They made sure equipment, facilities and technology supported the delivery of safe care. 

The diagnostic imaging department was located on the ground floor and provided a range of services, including MRI, CT, ultrasound, fluoroscopy and X-ray. The environment was well maintained and designed to support the safe delivery of care, with spacious and accessible clinical areas, appropriate waiting and changing facilities, and secure access arrangements where needed. Clear signage throughout the department helped patients navigate the service safely.  

Radiation areas were clearly marked with warning lights and restricted access controls. Within the MRI suite, authorised access lists and safety information were displayed in line with the medicines and healthcare products regulatory agency (MHRA) best practice. Equipment labelling to indicate magnetic resonance (MR) safety status was visible on equipment, and a 5-gauss line plan diagram was marked on the floor within the MRI suite to demonstrate the perimeter of the magnetic field, outside of which is considered a safe level of exposure. 

There were quality assurance (QA) processes for the imaging equipment. Staff had training to ensure they were competent to carry out QA. The department had an identified radiographer to ensure effective oversight. 

Lead aprons, which are protective garments worn to reduce exposure to ionising radiation, were available for staff to use when required. The aprons were well maintained and in good condition. The service carried out annual integrity checks to ensure the aprons remained effective and free from damage, helping to protect staff from unnecessary radiation exposure. 

All staff working with ionizing radiation wore personal radiation monitoring badges. These were monitored through a personal dosimetry programme provided by an approved dosimetry service. 

The service had a health and safety executive (HSE) registration certificate for use of ionising radiation. 

The service used a planned preventative maintenance (PPM) programme to ensure buildings and equipment were maintained safely and remained fit for purpose. Routine servicing and maintenance checks were completed in accordance with manufacturers’ recommendations and included oversight from medical physics experts. These arrangements were applied consistently across all imaging modalities. Records showed that imaging equipment had undergone the required testing and examinations to confirm safety systems and warning devices were functioning as intended. 

There were processes to ensure faults were addressed quickly and minimised disruption to patients. Staff told us the external maintenance provider responded quickly to repair requests and typically attended the hospital on the same day or the following day. This helped reduce downtime and supported the continuity of diagnostic services. 

The MRI local safety rules were aligned with current best practice guidance. Clear signage was displayed throughout the MRI area, including information about the strength of the magnetic field. The MRI scanners were equipped with emergency controls that allowed staff to stop a scan immediately and turn off power to the system in the event of an emergency. 

We checked consumable equipment and found all single use items were in date. Emergency equipment was available in the department. It was stored on a designated trolley, fully stocked, and all items were in date. Regular checks of emergency equipment were carried out. An anaphylaxis kit was available, and all stock was in date. Although uncommon, some patients can have a severe allergic reaction to contrast, which can progress to anaphylaxis. 

There was an MRI safe trolley and transfer board within the MRI scanning room to improve speed of evacuation.  

Patients could call for help during examinations and could use emergency call buzzers. Emergency pull cords were available in areas where patients were left alone, such as toilets. Microphones were used to allowed 2-way communication between staff and patients during scans. 

Clinical waste was separated and disposed of safely. Sharps bins were stored appropriately, labelled and not overfilled. 

There was enough fire safety equipment and clear fire exits. 

Safe and effective staffing

Score: 3

The service made sure there were enough qualified, skilled and experienced staff, who received effective support, supervision and development. They worked together well to provide safe care that met people’s individual needs. 

The service provided mandatory training in key skills. Data from the service showed the 95% training compliance target was met in 29 out of 33 modules The remaining 4 modules were at 91%. All staff had completed training on recognising and responding to patients with mental health needs, learning disabilities and dementia.  

Radiologists practised at the hospital under practising privileges arrangements and therefore did not complete the service’s mandatory training programme. Instead, they undertook required training through their substantive NHS employers. The hospital had oversight of training compliance and access to records confirming completion of relevant training. In addition to this, radiologists working under practising privileges were required to provide evidence of a current appraisal, and the service maintained an up-to-date practising privileges policy. Practising privileges allow suitably qualified and experienced healthcare professionals to provide services within a hospital without being directly employed by the organisation. 

Staff included 1 whole time equivalent (WTE) imaging manager, 6.2 WTE specialist radiographers, 0.8 WTE radiographer and 0.4 WTE imaging assistants. When needed, bank staff were used to maintain safe staffing levels.  

The service used a recognised staffing tool to plan staff levels and skill mix. The staffing tool was updated daily and reviewed by the imaging manager and hospital leaders at daily hospital meetings to ensure safe staffing levels. The safe staffing tool did not include the imaging manager to ensure non-clinical duties could be carried out. The imaging manager could work clinically if staffing levels were low due to absence, or to allow other staff to complete mandatory training, carry out audits or administrative duties.  

Each imaging modality was staffed in line with planned rotas, and there were enough colleagues available to support service delivery and allow time to take breaks. Leaders had identified and assessed the risks associated with lone working and had implemented measures to reduce these risks, including a sign-in process and access to support from the wider hospital team when needed.  

The service did not employ any substantive medical staff. Sixteen radiologists held practising privileges and reported on private patient scans. For NHS patients medical staff employed by the host NHS trust reported on their scans. 

The service held quarterly team meetings and daily huddles where staffing levels were discussed and key information was shared with staff.  

New staff and bank staff completed an induction programme tailored to both the service and their specific role.  

Leaders addressed performance concerns through formal management processes. Staff told us that difficult conversations were held where required and were supported by staff from the human resources team and senior leaders. Actions and discussions were documented, and managers worked with staff to understand the underlying causes of concerns and provide appropriate support. Where staff experienced difficulties adapting to changes within the department, leaders clarified expectations and reinforced the importance of collaborative working and information sharing.  

Training needs were identified and acted on. For example, an MRI staff member was due to attend an MRI safety course and cascade the learning back to colleagues. This demonstrates both identification of training needs and knowledge sharing within the team.

Infection prevention and control

Score: 3

The service assessed and managed the risk of infection. They detected and controlled the risk of it spreading and shared concerns with appropriate agencies promptly. 

The service managed infection risks well. The department was clean and free from unnecessary clutter. We found furnishings and equipment to be in good condition and appropriately maintained. Patient areas, including waiting rooms, toilets and changing facilities, were visibly clean and provided a suitable environment for care. 

Staff used appropriate equipment and infection prevention measures to reduce the risk of infection for patients, staff and visitors. The department and equipment were visibly clean and well maintained. There were cleaning schedules for each diagnostic imaging area, these demonstrated that routine cleaning was completed regularly. Imaging rooms and control areas were visibly clean, tidy and suitable for the safe delivery of care. 

Staff told us they cleaned equipment after patient contact. Equipment was labelled to show when it had last been cleaned. 

Staff followed recognised best practice for the cleaning and disinfection of ultrasound equipment. Ultrasound probes were cleaned between each patient using a three-step disinfectant wipe process and underwent further decontamination at the end of each day. Staff maintained records of decontamination activities in individual logbooks for each probe. This was in line with guidance from the European Society of Radiology Ultrasound Working Group, Infection prevention and control in ultrasound– best practice recommendations from the European Society of Radiology Ultrasound Working Group (2017). 

Staff followed infection prevention and control (IPC) procedures and used appropriate personal protective equipment (PPE) when required. Staff cleaned their hands regularly and used hand sanitiser. Staff adhered to bare below the elbow guidance, jewellery and nail varnish were not worn in clinical areas to support effective hand hygiene and reducing the risk of infection transmission. 

There were arrangements to manage infection prevention and control risks, including caring for patients with known transmissible infections. When required, patients with transmissible infections were allocated longer appointments and often scheduled at the end of clinic sessions to allow for enhanced cleaning of equipment and clinical areas following their visit. 

An up-to-date infection prevention and control policy, supported by additional guidance, was available to staff and had been regularly reviewed. Staff could access this information when needed to support safe practice and leaders ensured staff knew how to access it. 

The service monitored compliance with IPC standards through a programme of audits. These included audits of hospital cleanliness, aseptic non-touch technique, hand hygiene, sharps management and standard IPC practices. We saw evidence that actions identified during an August 2026 IPC walkaround had been completed, and audit findings were shared with staff through team meetings.

Medicines optimisation

Score: 3

The service made sure that medicines and treatments were safe and met people’s needs, capacities and preferences. They involved people in planning, including when changes happen. 

Patient Group Directions (PGDs) were used to support the administration of contrast agents for MRI and CT examinations. These PGDs had been appropriately authorised and implemented in line with relevant guidance. PGDs provide a legal framework that allows specified registered healthcare professionals to supply or administer certain medicines to defined groups of patients without the need for an individual prescription from a doctor or non-medical prescriber. 

At the time of inspection, PGDs were being used for contrast media. Contrast media are substances used to improve the visibility of internal structures and tissues during diagnostic imaging. Records showed that staff using PGDs had completed competency assessments and signed documentation confirming they understood and would comply with the requirements of the PGD. This provided assurance that medicines were being administered safely and within an appropriate governance framework. 

Medicines were stored securely and were readily available to staff when required. Medicines were in date, kept in locked cupboards, with access controlled through a secure key-safe system. Medicines that required storage within designated clinical areas were maintained at the correct temperatures in accordance with manufacturers’ instructions. Staff completed and recorded daily room temperature checks and understood the actions to take if temperatures fell outside the acceptable range. Contrast media were stored appropriately and could only be accessed by suitably trained staff, helping to ensure medicines were managed safely.  

The service did not store or administer controlled drugs. 

The department kept emergency medicines on resuscitation trolleys to ensure they were available for immediate use. Each clinical area was equipped to manage allergic reactions.  

Information about known allergies was captured through referral documentation and patient screening processes. Staff also confirmed allergy status with patients as part of the pre-examination safety checks. Service records showed one patient experienced a reaction to contrast media during the previous year; however, no harm was reported as a result of the incident.