• Hospital
  • Independent hospital

Ultraworld Scanning Services

Overall: Inadequate read more about inspection ratings

31A Pier Road, Erith, DA8 1TA

Provided and run by:
Ultraworld Scanning Services Ltd

Assessment report published 24 November 2026

On this page

Safe

Inadequate

24 November 2026

This means we looked for evidence that people were protected from abuse and avoidable harm.

This was the service’s first assessment under the safe key question. We rated it as inadequate.

The service needed to make significant improvements to safeguarding, staffing assurance, incident reporting, learning, governance and referral pathways. The service did not effectively protect people’s safety because it lacked effective systems to identify, assess, monitor and mitigate risks. The service needed to make significant improvements to safeguarding, staffing assurance, incident reporting, learning, governance and referral pathways. Although it had some arrangements for environmental safety, infection prevention and control, and equipment maintenance, these did not mitigate the wider failures in safety systems and oversight.  

The service breached Regulation 7, which relates to the requirements for Registered Managers; and Regulation 13, which relates to safeguarding service users from abuse and improper treatment. 

We have not awarded this service a score for Safe.

Find out about when we will not publish a key question score and what we look at when we assess Safe.

Learning culture

Score: 1

The service did not have an effective learning culture. Staff did not consistently recognise or report safety events, and the service could not show that staff investigated events or used learning to improve care.

Since the service registered in March 2022, staff told us they had not recorded any incidents or near misses or used the electronic reporting system. The provider did not supply an incident log, investigations, outcomes, themes or learning.

Staff did not consistently identify which events should be reported. Examples included lone working without a risk assessment and unavailable or untrained chaperones. The service also lacked a system to confirm that the receiving healthcare professional had received and acted on urgent or significant findings and onward referrals. Without these checks, staff could not identify referrals that had not been received or acted on or recognise and report these as safety events.

The incident policy required staff to report incidents within 24 hours and discuss learning at monthly quality meetings. During the assessment, records did not show that staff investigated events, shared learning or made changes. Following the assessment, the provider submitted records of 15 urgent-referral cases. However, these did not demonstrate that staff had recognised and reported any associated safety incidents, investigated them or used learning to improve care.  

The duty of candour policy described how to assess incidents against the threshold for a notifiable safety incident. It set out requirements to inform the patient or relevant person, provide an apology and follow up in writing. During the assessment, staff could not explain how they would apply the duty of candour in practice. We could not establish whether leaders understood the threshold for a notifiable safety incident or when these requirements applied.

During the on-site assessment, staff told us they had not recorded any incidents or near misses since registration in March 2022 and had not used the electronic reporting system. Following the assessment, the provider submitted records of 15 urgent-referral cases. These did not demonstrate incident investigations, learning, post-incident debriefing or staff support. As no incidents had been investigated, there were no examples showing how staff would be supported after a serious incident or adverse event. This reduced assurance that the service identified recurring safety concerns, learned from incidents and took action to reduce the risk of recurrence. 

Safe systems, pathways and transitions

Score: 1

The service could not demonstrate a reliable process for communicating significant findings to the relevant healthcare professional. Patient information and referral records did not consistently show how staff obtained the contact details needed for onward communication.

Patient information forms did not routinely collect General Practitioner (GP) or treating consultant details. This was despite the service’s indemnity arrangements requiring staff to send reports containing a potential diagnosis to an appropriate clinician. The service did not describe an alternative process for obtaining these details when staff needed them for onward communication or escalation. This reduced assurance that significant findings would be communicated to the appropriate healthcare professional to support timely clinical review.

Referral and admission arrangements did not consistently capture all the information staff needed to determine whether the service could meet patients’ needs. Records and processes also did not set out how staff would obtain the information required to communicate and escalate significant findings.

The service did not have a consistent system for sending reports containing a potential diagnosis to a consultant or GP. During the on-site assessment, staff initially told us they did not record incidents or near misses. Following the assessment, the provider submitted a record of 15 urgent-referral cases. Of these, 14 were marked as completed and 1 had no recorded status. The records did not show how referrals were made when GP contact details were absent.

Safeguarding escalation formed part of the service’s wider referral pathways. The adult and child safeguarding policies identified the registered manager as safeguarding lead and included referral routes and contact details for local safeguarding services and emergency support. However, during the assessment, staff referred to contacting a local hospital but did not clearly explain how they would use the documented internal and external escalation routes. This reduced assurance that staff would consistently direct concerns to the appropriate agency without delay.

The Registered Manager was responsible for receiving national safety alerts, assessing their relevance, sharing information with staff and monitoring actions. The service provided an external field safety notice about a potential cybersecurity vulnerability affecting imaging software, including actions to protect the security and availability of patient information. The provider did not supply a risk register, so records did not show that staff had assessed or recorded the alert within a formal risk-management process. Records also did not show how staff shared this or other alerts, incorporated them into clinical pathways or monitored actions to completion. 

Safeguarding

Score: 1

The service did not have sufficient assurance that safeguarding arrangements were implemented effectively. Staff knowledge, training records, vetting arrangements and safeguarding processes did not demonstrate that safeguarding concerns would be consistently identified, escalated and managed appropriately.

The provider could not demonstrate that all staff with patient contact or safeguarding responsibilities had completed safeguarding training appropriate to their role. The Registered Manager, who was the safeguarding lead, had completed level 3 adult safeguarding training in January 2025 and level 2 child safeguarding training in June 2026. The Nominated Individual had completed level 3 adult and level 2 child safeguarding training in September 2026. However the records supplied did not demonstrate that locum sonographers, reception staff and chaperones had completed safeguarding training appropriate to their roles. The provider did not demonstrate how it monitored safeguarding training across the workforce or identified when refresher training was due. There was also no evidence that an accountant who occasionally acted as a chaperone had completed safeguarding or chaperone training. A chaperone can protect women from abuse by healthcare professionals and the provider could not demonstrate that their chaperone processes   protected women from harm.

Leaders could not clearly explain how staff would identify, record and escalate safeguarding concerns in practice. Their explanations of how they would respond to concerns relating to female genital mutilation (FGM) or requests for gender-selection scanning were limited and inconsistent. The policies included local signposting routes and contact details. However, leaders referred to contacting a local hospital and did not clearly describe how they would use a clear internal escalation pathway or service-specific guidance identifying relevant safeguarding agencies in practice. This meant the provider could not demonstrate that women presenting with potential safeguarding concerns would be consistently identified, escalated and protected.

The Registered Manager was the service’s safeguarding lead and had direct patient contact, including during intimate examinations. Their Disclosure and Barring Service (DBS) Update Service subscription had expired approximately 12 months before the assessment and a replacement DBS check had not been obtained. The provider did not supply evidence that it had identified, assessed or mitigated risks arising from this lapse. As a result, the provider could not demonstrate effective oversight of the Registered Manager’s continuing fitness and suitability despite their safeguarding responsibilities and direct contact with patients. Following the assessment, the provider submitted evidence that the Registered Manager had applied for and received a new DBS certificate.

The service could not demonstrate that it had effective arrangements for the use of chaperones during intimate examinations. One staff member could undertake intimate examinations alone and there was no consistent process for offering a chaperone, recording the patient's decision, or checking that individuals acting as chaperones were appropriately trained, vetted and authorised. An accountant had occasionally acted as a chaperone; however, the provider did not supply evidence of training, DBS checks, recruitment checks or formal authorisation to undertake this role. The provider also did not supply evidence that patients had consented to the accountant acting as their chaperone. This reduced assurance that patients undergoing intimate examinations would be consistently offered support from a suitably trained and vetted chaperone and increased risks to their dignity, privacy and safety.

Staff responses did not demonstrate a consistent understanding of how to recognise and respond to abuse, discrimination, harassment or exploitation, including risks affecting people with protected characteristics. Although the safeguarding policy covered support for people who needed help with decision-making, the evidence reviewed did not show how staff applied these arrangements, including for people with a learning disability. This reduced assurance that staff would identify and respond to safeguarding risks affecting patients who needed additional support.

The service had current adult and child safeguarding policies. These outlined safeguarding responsibilities, referral arrangements, information sharing, partnership working, DBS requirements and specific safeguarding risks, including FGM, modern slavery, radicalisation, honour-based abuse and sex-selective abortion. However, staff were unable to consistently explain how they would apply these arrangements in practice.

Although the service only provided ultrasound examinations to adults aged 18 years and over, staff could not consistently explain how they would identify, escalate and respond to safeguarding concerns involving children disclosed through adult patients. This reduced assurance that concerns affecting children and young people would be recognised promptly and referred appropriately.    

Involving people to manage risks

Score: 2

The service gave patients information about examination risks, limitations and possible next steps, and obtained consent before proceeding. However, communication and advocacy support did not consistently enable all patients to participate fully in managing risks.

Patient questionnaires explained the purpose and limitations of scans, when patients might need an onward referral, and consent to share relevant information with National Health Service (NHS) providers. Before transabdominal or transvaginal examinations, patients confirmed that they understood the information and consented. Sample reports recorded findings, conclusions and recommendations to support discussions about further care.

Staff described seeking urgent medical support if a patient became acutely unwell, including calling an ambulance where emergency assistance was needed.

Questionnaires asked patients to identify disabilities and accessibility requirements. The service expected patients who required an interpreter to arrange their own and had no formal advocacy arrangements. Records did not show how staff assessed or met language or decision-making support needs. 

Safe environments

Score: 2

The service had established most environmental safety, equipment servicing and maintenance arrangements. However, the physical environment did not consistently protect privacy and confidentiality during consultations and examinations.

The service operated from a multi-use building. During the assessment, noise from another organisation in the building was clearly audible in the clinical area. The scan room had limited sound insulation. As appointments could involve sensitive information, intimate examinations and unexpected findings, conversations could be overheard outside the consultation room.

Patient areas, including reception and waiting areas, were clean, maintained and free from obvious environmental hazards. Toilet facilities were suitable, emergency contact information was available, and the Control of Substances Hazardous to Health (COSHH) cupboard was locked to restrict access to potentially harmful cleaning substances. Staff positioned computer screens to limit unauthorised viewing and generally stored reports and images securely. However, we found confidential records in an unlocked cupboard by the reception cupboard by reception. This was escalated to the Registered Manager, and the records were removed. Environmental cleaning audits recorded 100% compliance in July 2026 and 98% in August and September 2026. On 31 August 2026, 50 of 51 items were compliant; an unclean patient chair was cleaned and the action closed that day. September actions addressed the scan room floor and residual ultrasound gel.

The ultrasound machine underwent annual servicing and safety inspection on 13 September 2026. Functionality, probe condition, cleaning and electrical safety tests were satisfactory, and the machine was left in full working order. During the assessment, we found that equipment was clean and in good condition, maintenance labels were in date, suitable probes were available, and staff had completed image quality assurance checks. An Electrical Installation Condition Report completed on 18 September 2026 assessed the installation as satisfactory, required no remedial work and recommended the next inspection by September 2031.  

Health and safety arrangements included a designated lead, first aid provision and an automated external defibrillator in the reception and waiting area to help restore a normal heart rhythm during cardiac arrest. The service had a current fire safety policy. Staff could access emergency equipment, first aid supplies and contact numbers; they organised supplies and kept them in date and described how they would respond to an acutely unwell patient. The health and safety assessment identified the need for evidence of induction, role-specific and refresher training, and assessments required under the Control of Substances Hazardous to Health (COSHH) Regulations to manage risks from hazardous substances.

An external disability-access risk assessment completed on 22 September 2026 recorded audible alarms, including fire smoke detectors, unobstructed emergency exits and adequate escape routes. It also recorded that emergency evacuation procedures had been communicated to relevant staff. However, regular alarm servicing records were not available to the assessor. The assessment rated this gap as high risk and recommended regular servicing and weekly testing. It noted that maintenance was managed through the building management arrangements and that additional records might be held but had not been provided for verification. 

Safe and effective staffing

Score: 1

The service could not demonstrate that it had effective systems to oversee workforce assurance, competency or training compliance. The provider did not supply several requested workforce records, including staffing oversight information, competency records, training compliance data and assurance regarding temporary workers

We asked the provider for information about its workforce establishment, vacancies, turnover, sickness absence, staffing use and shifts covered by temporary staff. The provider did not provide the requested workforce data or records showing how it had monitored staffing capacity since registration.

The service was substantially operated by 2 senior sonographers, who were also directors and held the Registered Manager and Nominated Individual roles. Both also worked in NHS trusts outside this service. They delivered clinical care, managed the regulated activity and oversaw governance. The Registered Manager said both directors were self-employed and were not on the company payroll. The provider did not supply clear workforce records setting out employment or contractual arrangements, roles, and working patterns.

The provider supplied records confirming that the Registered Manager and Nominated Individual held sonography qualifications. However, it did not supply the requested workforce list identifying other staff, temporary workers and their roles. It also did not provide records showing professional registration, scope of practice or appraisal for locum sonographers.

Leaders said locum sonographers provided additional cover. However, records did not show when they worked, their induction or competency checks, or their familiarity with local policies and escalation arrangements.

The provider did not include the accountant who occasionally acted as a chaperone in its workforce information. It did not provide records showing their employment or contractual status, training, vetting, competence or authorisation to undertake chaperone duties.

The Registered Manager and Nominated Individual completed each other’s appraisals and internal reviews. They described reviewing scan images and reports together and seeking second opinions from each other when findings were uncertain. Records did not show that anyone outside this arrangement provided independent clinical supervision, competency review or professional challenge.

Training records showed that the Registered Manager and Nominated Individual had completed some mandatory training, including safeguarding. However, the provider did not supply a complete role-based training matrix or compliance rates for clinical, non-clinical and temporary staff. It also did not evidence training relevant to the accountant’s occasional chaperone duties.  

Infection prevention and control

Score: 1

The service could not demonstrate effective infection prevention and control systems. The provider did not supply the requested policy, governance records or assurance arrangements, or evidence that internal ultrasound probe decontamination was undertaken and monitored in line with expected standards. Positive observations of cleanliness and staff practice did not provide assurance that these processes were consistently implemented and monitored.

We requested the provider’s infection prevention and control (IPC) policy, governance records and assurance arrangements, but these were not provided. Records did not identify an IPC lead or show a provider-level audit schedule, training matrix or governance process for reviewing IPC risks, audit findings and actions.

The provider did not supply evidence demonstrating that internal ultrasound probe decontamination was undertaken and monitored in line with expected standards. Sample ultrasound reports recorded probe decontamination and transducer cleaning, but did not identify the methods or products used, confirm that staff followed manufacturers’ instructions or show that the provider audited decontamination practices.

An external Legionella risk assessment completed on 22 September 2026 rated the premises as medium risk. Outstanding actions included producing a written control scheme, completing monitoring records, allocating responsibilities, routinely descaling outlets and addressing hot-water temperatures below the expected level.

The provider did not supply a wider infection prevention and control audit schedule, trend data or audit evidence covering locum staff.

However, during the assessment, we found that clinical areas, equipment and ultrasound probes appeared clean and well maintained. The service provided handwashing facilities and alcohol hand gel, staff worked bare below the elbow, and they could access personal protective equipment (PPE). Staff stored consumables appropriately and kept them within their expiry dates.

The provider supplied IPC training certificates for the Registered Manager and Nominated Individual. Following the assessment, the provider submitted a hand-hygiene audit completed on 30 September 2026. The audit scored 100% (10 of 10), assessed the 2 senior sonographers against the World Health Organization (WHO) 5 Moments for Hand Hygiene and recorded no actions. Some historic water-temperature monitoring records were also available.

Medicines optimisation

Not yet scored

We did not look at Medicines optimisation during this assessment. There is no previous rating for the Safe key question so we cannot yet publish a score for this area.